News, technical articles and suppliers for the coil winding industry

Coiltech Germany 2027, 17-18 March 2027, Messe Augsburg - international coil and winding exhibitionAdvertisement
Article

Common Terms in Coil Winding and Magnet Wire Production

By Will Hunsdorf | 1 Nov 2026

Coil makers and wire makers use words that sound alike and mean different things. These definitions come from the NEMA magnet wire standard overview and a technical article on coil winding.

Wire terms

  • Magnet wire. NEMA defines it as an insulated electrical conductor, usually copper or aluminium, that creates a useful electromagnetic field when wound into a coil and energised. It is also known internationally as winding wire. See magnet wire vs enamelled copper wire.
  • MW number. The NEMA standard labels each wire type with an MW number followed by -C for a copper conductor or -A for aluminium, for example MW 15-C.
  • NEMA MW 01000. The standard that covers magnet wire general requirements, specifications and test methods in one document. It replaced the designation MW 1000 effective 2025 and is equivalent to it, so compliance with earlier editions is not affected.
  • Build and grade. NEMA refers to single build as Grade 1, with heavy and triple build as Grade 2 and Grade 3. Build is the thickness of the insulation layer, and a higher build has more insulation.
  • Thermal class. The temperature rating group of a wire type, listed in the NEMA standard. See how to select enamelled copper wire and motor winding temperature classes.

Standards terms

The NEMA overview says that NEMA and IEC (International Electrotechnical Commission) specifications and test methods differ, that Annex C of MW 01000 cross-references the two, and that not every NEMA specification has an IEC equivalent. NEMA's continuity requirement for single build wire reflects present manufacturing equipment more closely than the IEC requirement, while IEC 60317-0-1:2013 brought closer agreement for heavy and triple build.

Winding terms

  • Fill factor. The ratio of the area of electrical conductors to the available winding space. Because round wire leaves gaps and insulation needs room, it is always below one. See rectangular vs round magnet wire.
  • Layer winding. Wire laid in successive layers on a bobbin or former.
  • Wild winding. A layer structure in which the wire is placed helically in each layer, the direction reverses between layers and the wires cross and settle into the gaps of the layer below, without guiding each turn.
  • Orthocyclic winding. A layered winding in which the upper layer sits in the grooves of the lower layer to achieve the tightest packing of round wire.
  • Traverse. The back-and-forth movement of the wire guide along the coil as the spindle turns. See the article on traversing systems.
  • Direct and indirect winding. Winding straight onto the part, or onto a carrier first.

Using the terms

When you order wire, give the type by MW or IEC number, the conductor, the size in AWG or millimetres, the build and the thermal class. When you describe a winding, say what you mean by layers, turns per layer and fill. Clear terms save sample cycles.

Frequently asked questions

What is magnet wire?

An insulated conductor, usually copper or aluminium, wound into coils to create an electromagnetic field. Also called winding wire.

What is MW 01000?

The NEMA magnet wire standard, formerly MW 1000, effective as the new designation in 2025.

What does build mean?

The thickness of the insulation layer. Single, heavy and triple build are Grades 1, 2 and 3.

What is fill factor?

Conductor area divided by available winding space.

What is wild winding?

A layer winding in which wires cross and settle into gaps of the layer below without exact placement.

Sources

  • NEMA: MW 01000 magnet wire standard overview (definition of magnet wire, structure of the standard, thermal class, comparison with IEC)
  • Wikipedia: coil winding technology (layer winding, wild winding, fill factor)