Copper Purity and Electrical Conductivity in Magnet Wire

By Ron Hollweck | 17 Nov 2026

Copper is chosen for coils because it conducts well. How well depends on how pure it is and on how the wire has been treated. This guide covers the terms.

IACS: the reference

IACS stands for International Annealed Copper Standard. A wire maker explains that pure soft-annealed copper defines the 100 percent IACS baseline for measuring conductor conductivity. A mill datasheet lists the same 100 percent IACS as 58 MS/m for its copper in the soft condition.

Common copper grades

  • Cu-ETP (electrolytic tough pitch, C11000): a producer datasheet gives copper at a minimum of 99.90 percent and oxygen at a maximum of 400 ppm, with electrical conductivity of a minimum of 100 percent IACS. It is described as the most widely used copper because of its conductivity, corrosion resistance and workability, and as prone to hydrogen embrittlement in a reducing atmosphere.
  • Cu-OF (oxygen-free, C10200): the same producer lists copper at a minimum of 99.95 percent, oxygen at a maximum of 10 ppm, and conductivity of 100 percent IACS, with no susceptibility to hydrogen embrittlement. It states that the specified conductivity applies to the soft condition only.

The datasheet for ETP also lists conductivity by temper under the European standard: minimum 100 percent IACS for one temper, 98.3 percent for a harder one and 96.6 percent for the hardest listed. Harder tempers conduct less.

Why cold work and annealing matter

Drawing distorts the crystal structure. One article explains that defects scatter electrons, so cold-drawn copper has slightly lower conductivity than annealed copper, and that annealing recovers conductivity to near 100 percent IACS. See why copper wire is annealed before enamelling.

Purity and drawing

Grade also affects forming. The producer datasheet says oxygen-free copper is capable of withstanding extra deep drawing and severe forming because there are no oxides in the structure, and that it is superior to ETP in this respect. For fine wire, the maker decides what rod grade suits the drawing the wire will receive. See how copper rod is drawn into fine magnet wire.

What this means for magnet wire

  • Conductor resistance depends on the copper's conductivity and on the wire's size. Use the datasheet resistance, not a number from memory.
  • Soft annealed wire is the usual magnet wire condition. Ask the maker for the temper and the resistance values for your size.
  • Oxygen content affects the choice of grade. Ask which copper rod grade the maker uses.
  • The standard for the wire sets resistance limits. Use the standard or the maker's data. See what is enamelled copper wire.

Frequently asked questions

What is 100 percent IACS?

The conductivity of pure soft annealed copper, the reference for measuring other conductors.

Is oxygen-free copper more conductive than ETP?

Both datasheets list 100 percent IACS in the soft condition. The differences are oxygen content and behaviour in some processes.

Does hard-drawn wire conduct less?

Yes, slightly, because of defects from cold work. Annealing recovers it.

Which copper is used for magnet wire?

It depends on the maker. Ask for the rod grade.

Where do I find resistance values?

In the wire datasheet or the governing standard.

Sources

  • Aurubis: Cu-ETP datasheet (copper grade, composition, minimum conductivity)
  • Aurubis: C10200 Cu-OF datasheet (oxygen-free copper, conductivity, soft condition note)
  • New England Wire Technologies: what is annealing in wire manufacturing (IACS baseline, work hardening)
  • FCT Metal: understanding the annealing process and copper wire flexibility (cold work lowers conductivity)