News, technical articles and suppliers for the coil winding industry

Coiltech Germany 2027, 17-18 March 2027, Messe Augsburg - international coil and winding exhibitionAdvertisement
Article

Corona-Resistant Magnet Wire for Inverter-Fed Motors

By Horst Kunz | 20 Nov 2026

A motor on a variable speed drive sees voltage pulses with fast edges, not a clean sine wave. These can start partial discharges in the winding. The wire industry's answer is corona-resistant enamel.

The problem

A conference paper on drive motor insulation says variable speed drive use causes partial discharges, which are the most common reason for winding damage, and that magnet wire makers have developed products more resistant to them. Partial discharge activity and space charge accumulation depend on the supply waveform, in frequency and shape, to an extent that depends on the material, according to a study of corona-resistant enamelled wires.

PDIV and RPDIV

The partial discharge inception voltage, PDIV, and the repetitive partial discharge inception voltage, RPDIV, are key parameters for the insulation system of machines fed by converters, according to a 2018 paper that analyses the definitions in IEC 60034-18-41 and 60034-18-42. The paper says these quantities have a fundamental role in the design and qualification of Type I insulation, which must last its whole life without partial discharges. It also warns that the two definitions can differ in ways that significantly affect insulation design.

Type I insulation

For purely organic, Type I, insulation systems, the inception of partial discharges is the end-of-life criterion under IEC 60034-18-41, according to a 2016 paper on inverter-fed motors. For these motors the design aim is a PDIV high enough that discharges do not start in service. A 2019 paper proposes a model for the PDIV of magnet wires, including the effect of elevated temperature, across the wire geometries in IEC 60317-13.

How corona-resistant wire is built

A manufacturer's insulation guide describes a dual coat system: a polyester base coat modified with THEIC, combined with a corona resistant shield coat of polyamide-imide overcoat designed to withstand severe voltage stresses. It lists inverter duty and high voltage motors as the applications. This is one maker's description, and other makers use other formulations.

What to check beyond corona resistance

A Nordic study of a corona-resistant wire checked whether its other properties were adequate against a reference wire, using dimension, mandrel, peel, breakdown voltage and pin hole tests. A buyer should ask the same.

  • PDIV or RPDIV data at your temperature and waveform.
  • Thermal class. See thermal class of magnet wire.
  • Mechanical test data for winding stresses.
  • Insulation grade and build.
  • Maker's guidance for your inverter voltage and cable length.

Frequently asked questions

Why do inverters damage winding insulation?

Voltage pulses can cause partial discharges. Drives are described as causing them, and they are a common reason for winding damage.

What is PDIV?

The voltage at which partial discharges begin.

What is Type I insulation?

A purely organic insulation system. Under IEC 60034-18-41 the start of partial discharges is its end-of-life criterion.

What is the wire made of?

One maker lists a modified polyester base coat with a polyamide-imide corona resistant shield coat.

Is corona-resistant wire enough on its own?

The whole insulation system matters. Ask for data and design with the motor maker.

Sources

  • Nordic Insulation Symposium 2018: insulation system for variable speed driven motors, performance of a corona resistant magnet wire
  • IEEE EIC 2018: definition of PDIV and RPDIV for insulation systems of inverter-controlled rotating machines (IEC 60034-18-41 and 18-42, Type I insulation)
  • IEEE EEIC 2001: evaluation of corona-resistant magnet wires through partial discharge and space charge measurements
  • IEEE Electrical Insulation Magazine 2019: insulation design of low voltage motors fed by PWM inverters (PDIV of magnet wires; IEC 60317-13)
  • IEEE ICD 2016: design criteria for inverter-fed Type 1 motors (IEC 60034-18-41, partial discharge inception as end-life criterion)
  • MWS Wire Industries: magnet wire insulation guide (insulation types and applications, including corona-resistant systems)