News, technical articles and suppliers for the coil winding industry

Coiltech Germany 2027, 17-18 March 2027, Messe Augsburg - international coil and winding exhibitionAdvertisement
Article

How generator windings are made: from random-wound coils to Roebel bars

By Coil Winding News | 25 Nov 2026

Stator winding of a hydroelectric generator with rows of form-wound coils around the bore

A generator converts mechanical power into electrical power through the same principles of electromagnetic induction that a motor uses in the opposite direction, and much of the winding practice is shared between the two. But scale changes everything. A small wind turbine generator may use windings much like an industrial motor's, while a power-station turbogenerator carries some of the most demanding coils in electrical engineering. This article looks at how generator windings are made across that range.

Random-wound or form-wound

For smaller generators, including many wind turbine generators, one design choice is between random-wound and form-wound coils. Guidance from the Electric Power Research Institute on wind generator maintenance describes the dividing line in the machines it covers: random-wound coils are typical below 1,000 V, while form-wound coils, recognizable by their rectangular cross-section, are used at higher voltages.

In a random-wound stator, round enameled wire is wound and inserted much as in a motor, with the varnish film on the wire itself serving as conductor insulation, plus slot insulation, impregnating resin, wedges and finishing varnish. In a form-wound stator, each coil is made to shape first, and the insulation is a tape system built up around the conductors: coil conductor insulation, ground wall insulation, vacuum pressure impregnation resin, corona protection tape and winding bracing, all assembled to leave minimal voids.

Inside a power-station generator

At the top end, turbogenerators driven by steam or gas turbines show how far coil making can go. A stator winding construction guide from the Brazilian manufacturer WEG for its 2-pole turbine generators describes the main elements:

  • Coils are precisely formed in steel cradles, as full-loop or half-loop multi-turn or single-turn coils depending on frame size.
  • Each turn is insulated with mica glass tape, and the main ground insulation is also mica glass tape, with semiconducting materials applied on the outside for corona protection.
  • The copper strands inside a coil are transposed, in a full-loop transposition or, for half coils, a Roebel transposition. Transposition swaps each strand's position along the coil so that circulating currents and extra losses between strands are kept under control; the Roebel bar is the classic way of doing this in large machines.
  • Insulation is consolidated by vacuum pressure impregnation (VPI) with an epoxy-mica system, either after winding into the stator or, for the largest half coils, before.
  • Resistance temperature detectors are placed between coil sections in the slots to monitor hot spots, and the coil ends are braced, wedged and lashed so nothing moves under short-circuit forces.

Hydro and wind

The photograph above shows the stator of a hydroelectric generator, where large-diameter, slow-speed machines carry many poles and form-wound coils around a huge bore. EPRI's guidance shows that mainstream wind turbine generators use the full range of construction, from random-wound stators at 690 V to form-wound machines at higher voltages.

The common thread

From a 690 V wind turbine stator to a multi-hundred-megawatt turbogenerator, generator winding is about the same three things: putting the right copper in the right place, insulating it for decades of thermal and electrical stress, and bracing it against forces that only appear on the worst day of the machine's life. The size of the machine changes; the discipline does not.

Technical details are drawn from EPRI guidance on wind energy generator maintenance and a WEG stator winding construction guide for 2-pole turbine generators, checked 25 November 2026. This article is not design or maintenance advice.

Image: the stator winding of the No. 2 generator at Wimalasurendra Power Station, Sri Lanka. Photo: Astronomyinertia, CC BY-SA 3.0, via Wikimedia Commons; resized from the original.