News, technical articles and suppliers for the coil winding industry

Coiltech Germany 2027, 17-18 March 2027, Messe Augsburg - international coil and winding exhibitionAdvertisement
Article

How to Set Wire Tension for Enamelled Copper Wire

By Will Hibbard | 25 Nov 2026

Setting tension is not a matter of feel. The wire maker publishes a maximum recommended tension for each wire size, and the winder is set as a fraction of that figure.

Start from the chart

A tension chart from Phelps Dodge Magnet Wire engineering data, distributed by a winding machine maker, says uniform tension is critical to a quality product and the most overlooked detail of coil winding. It gives a maximum recommended tension by AWG wire size, and says you will typically use a value equal to 50 to 80 percent of the maximum so the magnet wire is not elongated and damaged during winding. A second chart, from a winding automation supplier, lists a maximum tension and a recommended tension at 75 percent of it for each AWG size, in centinewtons. Read the figure for your wire size from the chart, or from your own wire supplier's data, instead of guessing.

The charts are for bare conductor size of copper magnet wire. Aluminium, flat wire and fine wire may have different limits, so use the data for the wire you buy. See how to select enamelled copper wire.

Set it on the machine

  1. Find the maximum tension for your wire size and choose a starting value within 50 to 80 percent of it.
  2. Set the tensioner and measure the force on the wire at the point where it leaves the guide, with a tension meter, at winding speed if you can.
  3. Wind a trial coil and look at the layers. A loose coil or gaps point to low tension. A stretched or thinned wire, or breaks, point to high tension.
  4. Adjust in small steps and record the setting in the recipe.

A set-up guide says too low a tension can loosen the coil and too high can stretch or break the conductor, and that tension should be tested under actual winding conditions and be stable throughout the operation. See how to set up a coil winding machine.

Why tension drifts

  • Spool diameter changes as the wire pays off. An article on tensioning in winding describes dancer arms and load cells feeding back to a controller that adjusts a brake or clutch to hold tension constant. See wire tensioners for coil winding machines.
  • Speed changes. Acceleration and deceleration change the pull on the wire.
  • Wire path: rough guides, rollers that bind or wire catching on a flange.
  • Worn tensioner parts and sensor faults.

When to lower it

A hysteresis brake setup described in the same article uses a slight taper tension on the end of a coil. Fine wire and thin enamel need extra care. When wire breaks, check tension first, then the wire path. See why copper wire breaks during coil winding.

Frequently asked questions

What tension should I use?

A value of 50 to 80 percent of the wire maker's maximum recommended tension for the wire size, per the Phelps Dodge chart.

Where do I find the maximum?

In the wire maker's tension chart for your wire size.

How do I check tension?

Measure it with a tension meter at the guide and wind a trial coil.

What does too much tension do?

It can stretch or break the conductor.

Does tension stay constant by itself?

No. Spool size, speed and wire path change it, so closed loop control or regular checks are needed.

Sources

  • Phelps Dodge Magnet Wire engineering data: recommended magnet wire tension chart by wire size (50 to 80 percent of maximum tension; distributed by a winding machine maker)
  • Winding Automation: AWG, metric and inch equivalent dimensions and wire tension for copper magnet wire (maximum and recommended 75 percent tension)
  • Machine Design: motion scenarios, tensioning in winding (magnetic particle clutches and brakes, hysteresis brakes, dancer and load cell feedback)