Above a few kilovolts, a motor winding cannot rely on enamel and varnish. It needs an insulation system built for voltage stress, built from layers around each coil.

The parts of the system

An EPRI guide describes the insulation of a form wound stator coil as including wire covering, turn insulation, ground insulation, and an outside protective layer of polyester or fibreglass cloth. A paper on insulation for large machines says modern systems for stator windings operating above about 4 kV are built from similar materials: strand insulation, glass or Dacron, mica groundwall insulation, and end grading made of silicon carbide loaded tapes or paints. The same paper notes class F capability, dimensional stability and elimination of significant voids as design goals.

Ground wall layers

NEMA's course material lists layers of half-lapped mica tape for the ground wall of form wound stators by voltage class: 2 layers up to 3 kV, 3 layers for 3.1 to 5 kV, 5 layers for 5.1 to 7 kV and 9 layers for 7.1 to 13.2 kV. These are one reference's example values, and a design is set by the maker.

Two ways to make it

  • VPI (vacuum pressure impregnation): the coils or bars are wrapped with dry mica tape, held with a small amount of epoxy adhesive. They go through a vacuum cycle that removes volatiles and humidity, then resin is introduced and pressurised to drive it into the insulation, and the part is cured in an oven. A tape maker describes VPI mica tapes designed for main wall and end-winding insulation.
  • Resin rich: tapes pre-wetted with semi-cured, B-staged epoxy are applied and then heated and compressed, by press or autoclave, so the resin flows and cures the layers together.

The author of the large machine paper says that when the systems are adequately designed and made under proper quality control, both methods perform similarly, with the caveat that the system designer has done the right homework and the process is stable and well controlled.

Process control

The EPRI guide says good VPI processing is as important as good resin selection, that the resin supplier defines the procedure, and that the key steps are preparation, vacuum treatment, pressure treatment and oven cure. Preparation covers resin temperature, viscosity, oven temperature monitoring and vacuum gauge accuracy.

What to ask for

  1. The insulation system type and thermal class. See thermal class of magnet wire.
  2. Voltage class and the number of tape layers.
  3. Partial discharge test results on coils or the stator.
  4. The VPI or resin-rich process controls used.
  5. Winding data, so a rewind can match it. See induction motor winding design and manufacturing basics.

Frequently asked questions

What is mica tape for?

It is the main ground wall insulation in high-voltage stator windings.

What does VPI mean?

Vacuum pressure impregnation: a process that fills the insulation with resin under vacuum and pressure.

Is VPI better than resin rich?

One large-machine paper says both can perform well if designed and controlled properly.

Why is there grading at the ends?

End grading, using silicon carbide tapes or paints, is listed as part of systems above about 4 kV.

Who sets the number of layers?

The machine maker, from the voltage and design.

Sources

  • EPRI: guide for electric motor stator winding insulation design, testing and VPI resin treatment
  • Andritz Hydro paper: insulation comparison, VPI produced versus resin rich (stator insulation for large machines)
  • Von Roll: insulating systems for high-voltage rotating machines (VPI mica tapes for main wall and end-winding insulation)
  • NEMA: alternating current motors in detail (ground wall insulation layers by voltage class, VPI)