News, technical articles and suppliers for the coil winding industry

Coiltech Germany 2027, 17-18 March 2027, Messe Augsburg - international coil and winding exhibitionAdvertisement
Article

Motor Rewinding vs New Motor Winding

By Ron Hollweck | 5 Nov 2026

When a motor fails, the choice is between rewinding it and buying a new one. The answer depends on facts about the motor and the job, and on the quality of the repair.

Decision points

A repair specialist's presentation lists the decision points to consider together:

  • Is the present failure catastrophic?
  • Is there evidence of a prior catastrophic failure?
  • Is the rotor damaged?
  • Are other mechanical parts severely damaged?
  • Is it an EPAct (IE2) or NEMA Premium (IE3) motor?

It adds that a catastrophic failure typically does considerable damage to the stator core, the windings and other parts such as the rotor, shaft, bearings and end brackets, and replacement may then be the most economical choice. Evidence of earlier failures may appear only after disassembly, such as damaged core laminations, rotor bars or end rings, or a shaft that has bent again. If the failed motor suits the application, assess the stator core. If core damage is significant, or if the motor exceeded its rated temperature rise before failing, a new motor may cost less than repairing a badly degraded core. Also reassess the application, because duty cycles change.

Does rewinding cut efficiency?

An EASA and AEMT study, reported in 2003, tested 23 motors of 50 to 300 hp before and after rewinding, with efficiency measured to IEEE 112 Method B. It described the claim that rewinding inevitably lowers efficiency as mythic, and reported that best rewind and repair practices maintain efficiency within plus or minus 0.2 percent. In its multiple-rewind stage the average efficiency improved by 0.2 percent when best practices were followed. Variation in the other stages ran from minus 0.7 to plus 0.8 percent, with the best results when process controls were used.

The study traced losses to specific causes: copper loss from poor control of mean length of turn, stray loss from stripping damage, core loss from the burnout process and friction loss from over-greasing bearings. It found that burning out below 360 C may not break down the varnish and may need extra force to remove the coils, which can splay teeth and raise stray loss, and that burning out hotter than 360 C for organic core plate, or 400 C for inorganic, risks damage to the interlaminar insulation and higher core loss.

Practical advice

  1. Ask the repairer about burnout temperature control, winding data recording and copper content control.
  2. Ask for efficiency or no-load tests before and after.
  3. Compare the repair price with the replacement price and the energy cost over the motor's life.
  4. Record the original winding data before stripping. See induction motor winding design and manufacturing basics.

These findings are for larger induction motors in a specific study. Smaller motors and other repair practices may differ.

Frequently asked questions

Does rewinding always lower efficiency?

Not in the EASA and AEMT study, which found best practices maintain efficiency within 0.2 percent for the motors tested.

When is replacement better?

When damage to the core, rotor or other parts is significant, or when the motor does not suit the application.

What temperature should burnout use?

The study found 360 C was a lower limit and gave maximum figures by core plate type. Follow your repairer's controlled process.

What losses can poor rewinding raise?

Copper, stray, core and friction losses.

Does the study cover small motors?

It covered 50 to 300 hp. Earlier studies on smaller motors differ.

Sources

  • EASA and AEMT study of motor repair impact on efficiency, ACEEE 2003 (efficiency before and after rewinding, burnout, loss analysis)
  • Goding Electric: electric motors, repair or replace (decision points: failure type, core condition, efficiency class, lifecycle cost)