Round Enamelled Copper Wire Sizes: AWG, Diameter and Overall Dimensions
Round enamelled copper wire is the most common magnet wire shape. Its size is given either as an American Wire Gauge (AWG) number or as a metric diameter in millimetres. This guide shows how to convert between them and why the size on a datasheet is not always the size you measure on the spool.
How AWG works
AWG is a stepped gauge for round, solid, non-ferrous conductors, defined in ASTM B 258. A higher number means a thinner wire. Two sizes anchor the scale: 36 AWG is 0.005 inch (0.127 mm) and 0000 AWG is 0.46 inch (11.68 mm). The ratio of those diameters is 1 to 92, over 39 steps, so each step changes the diameter by the same factor, about 1.1229.
The diameter for a given size n is: d = 0.127 mm x 92^((36 - n) / 39). The exponent of 92 is the whole fraction (36 - n) / 39, so subtract n from 36 first, divide by 39, then raise 92 to that power.
Worked examples
- 20 AWG: Nominal bare diameter (inch): 0.0320; Nominal bare diameter (mm): 0.813
- 30 AWG: Nominal bare diameter (inch): 0.0100; Nominal bare diameter (mm): 0.254
- 36 AWG: Nominal bare diameter (inch): 0.0050; Nominal bare diameter (mm): 0.127
The inch values are the nominal bare diameters in one magnet wire manufacturer's published copper magnet wire data. The millimetre column is the same value converted at 25.4 mm per inch. The formula gives the same figures to within rounding (for 30 AWG, 0.2546 mm). Sizes carry a tolerance: the same data lists 30 AWG at 0.0099 to 0.0101 inch, minimum to maximum. Because each step is a constant factor, six gauge steps change the diameter by about two times. Wire gets thinner by half every six numbers.
Bare diameter and overall diameter
AWG tables describe the bare conductor, before any enamel is applied. A published magnet wire reference states that its dimensions are bare conductor values, before enamel or self-bonding layers add to the size. The wire on the spool is larger.
How much larger depends on the insulation build. For enamel, the common build names are single, heavy, triple and quad. Build relates to the dielectric strength and mechanical protection the wire needs, and a heavier build adds more to the overall diameter. The exact limits for each size and build are in the product standard or the supplier datasheet, so use those when you calculate how many turns fit in a slot or bobbin. See also wire insulation in coil winding.
Metric sizes
AWG is a North American system. Many datasheets list the nominal conductor diameter in millimetres next to the AWG number. Before you compare two products, check whether a metric size is a diameter or something else, and use the same basis for both.
Practical checks
- Confirm whether a stated size is bare or overall.
- Check the tolerance on diameter in the standard or datasheet.
- Do not use AWG for rectangular wire. AWG refers only to round and square wire.
- Measure with a suitable micrometer at the right point, not on the enamel surface alone, when you need conductor size.
Frequently asked questions
What does a higher AWG number mean?
A thinner wire. Each step up reduces the diameter by the same factor, about 1.1229.
Is the AWG diameter the size of the enamelled wire?
No. AWG tables give the bare conductor. The overall diameter includes the enamel build, which is larger.
How do I convert AWG to millimetres?
Use d = 0.127 mm x 92^((36 - n) / 39), where the exponent is the whole fraction (36 - n) / 39. For example, 30 AWG is about 0.254 mm (0.0100 inch).
Can I use AWG for rectangular wire?
No. AWG applies to round and square wire only.
Where do I find overall diameter and tolerance?
In the product standard or the supplier datasheet for the exact type and build.
Sources
- MWS Wire Industries: copper magnet wire data (nominal, minimum and maximum bare diameters by AWG size)
- ASTM B258: standard nominal diameters and cross-sectional areas of AWG sizes of solid round wires (title and scope only; standard text is paywalled and was not read)
- Engineering Bible: AWG formula d = 0.005 in x 92^((36-n)/39), per ASTM B258
- Wikipedia: American wire gauge (definition, anchors, 92 ratio, formula)
- EIS: What is magnet wire? (AWG scope, insulation builds)
- Cromwell International: copper wire and AWG formulas (cross-check of gauge definition)