Single-Phase Motor Winding: Main Types and Layouts
Single-phase motors run on household and light commercial supplies. Their winding is different from three-phase because a single phase does not make a rotating field on its own.
Two windings in the stator
A microelectronics maker's note and university lecture notes both describe the same layout: the stator carries a main (running) winding and an auxiliary (starting) winding, placed in the slots, with the auxiliary winding displaced by 90 electrical degrees. The two windings are connected in parallel to a single source. A microelectronics maker explains that connecting a capacitor in series with the auxiliary winding puts the currents in the two windings out of phase, and that this phase difference generates the torque to start rotation.
Main types
- Shaded-pole: a squirrel cage rotor with extra shade windings at the pole corners. These are not connected to the supply. They carry an induced current that delays part of the field, giving low starting torque. One source gives a typical range of 1/20 to 1/6 horsepower.
- Split-phase: a run winding and a start winding, usually up to about 1/3 horsepower according to one source. The start winding has high resistance and low reactance compared with the main winding, which gives the phase difference. A centrifugal switch takes it out when the motor reaches about 70 to 80 percent of speed.
- Capacitor-start: a split-phase motor with a capacitor in series with the auxiliary winding. A simulation reference says the auxiliary and main windings have the same number of turns and the capacitor makes the auxiliary current lead the main by about 80 electrical degrees.
- Capacitor-start capacitor-run: the auxiliary winding stays active in the run state with a run capacitor. It is listed as one of four types in the same reference.
Start switching
The start capacitor is a short-duty electrolytic type, disconnected when the motor reaches about 75 percent of full-load speed according to the microelectronics maker. It warns that using it longer than necessary can cause problems. The switch that does this is a centrifugal switch on many motors, and electronic control on others.
What to record before rewinding
- Which winding is main and which is auxiliary, by resistance. The start winding has higher resistance in split-phase motors.
- Slots, coil spans and number of turns of each.
- Wire size and insulation of each winding.
- Direction of connection and the position of the capacitor and switch.
- Nameplate data.
Measure and record before stripping. See motor winding resistance testing for how to measure winding resistance.
Frequently asked questions
Why does a single-phase motor need two windings?
A single winding makes a pulsating field and cannot start the rotor. The second winding gives the phase shift to start.
What is a shaded-pole motor?
A small motor with shade windings that produce a delayed field for starting.
What does the centrifugal switch do?
It disconnects the start winding at about 70 to 80 percent of speed.
Is the start winding the thin one?
In split-phase motors it has higher resistance than the main winding.
Can the auxiliary winding stay on?
Yes, in capacitor-run designs.
Sources
- STMicroelectronics: single phase AC induction motor basics (main and auxiliary winding, shaded-pole, split-phase, capacitor)
- MathWorks: single-phase induction machine model (split-phase, capacitor-start, main and auxiliary windings, disconnection speed)
- Lecture notes: single-phase induction motors (main and auxiliary winding, centrifugal switch, 90 electrical degrees)