How to Measure Copper Wire Diameter and Ovality
Diameter looks simple to measure. For magnet wire it is not, because the wire is soft, the tolerances are small and there are two diameters to think about: the bare conductor and the insulated wire. IEC 60851-2 sets the method for winding wires. This article follows the sample copy of the standard and does not replace it.
Equipment
The standard says the equipment must have a resolution of 2 micrometres or less for wires over 0.200 mm, and 1 micrometre or less for wires up to and including 0.200 mm. Mechanical contact micrometers and optical non-contact micrometers may both be used. If the contact type is used, the ratio of measuring force to anvil diameter must fall in the range the standard gives for the wire type. For enamelled round wire the standard lists anvil diameters of 2 to 8 mm for the finest wire and 5 to 8 mm for larger wire, with different force ratios per size. If optical micrometers are used, the average of the readings is recorded as the diameter. If specific equipment must be used, the customer and supplier agree it.
Bare conductor diameter, round wire
- Take a straight piece of wire.
- Remove the insulation by a method that does not damage the conductor.
- Make three measurements of the bare diameter at points evenly distributed around the circumference.
- Report the three single values. The mean is the conductor diameter.
Out-of-roundness
The standard defines out-of-roundness as the maximum difference between the three readings, and says it must be reported. That is the figure to compare against the tolerance in the product standard or datasheet.
Rectangular wire
For rectangular wire the standard calls for one measurement of each of the two dimensions at each of three places, with the insulation removed at those places. The mean is the width or thickness. For overall dimensions of insulated rectangular wire, three places at least 100 mm apart are measured, and where the wire is wider than the spindle, readings are taken at the centre of the face and over the edges; if they differ, only the highest is noted.
Overall diameter
For insulated round wire over 0.200 mm, the standard measures at each of two places 1 m apart, three readings evenly distributed around the circumference, giving six values. The mean is the overall diameter. The increase in dimension due to the insulation is a separate determination in the standard.
Practical points
- Use light, constant measuring force. Soft wire is easy to squash.
- Measure at several places along the length.
- Record the equipment and method with the result.
- Compare with the nominal and tolerance in the product standard. For sizes, see round enamelled copper wire sizes.
Frequently asked questions
How many readings are taken on round wire?
Three around the circumference at one place for the bare conductor, with the mean reported.
What is out-of-roundness?
In IEC 60851-2, the maximum difference between those readings.
Can I use a laser micrometer?
The standard allows optical non-contact micrometers, with the average reading recorded.
What resolution is needed?
2 micrometres or less over 0.200 mm, and 1 micrometre or less up to 0.200 mm.
Do I strip the enamel first?
For conductor diameter, yes, by a method that does not damage the conductor.
Sources
- IEC 60851-2: winding wires, test methods, determination of dimensions (sample copy; equipment resolution, three readings, out-of-roundness)