News, technical articles and suppliers for the coil winding industry

Coiltech Germany 2027, 17-18 March 2027, Messe Augsburg - international coil and winding exhibitionAdvertisement
Article

How to Read a Three-Phase Motor Winding Diagram

By Fred Kunkel | 2 Nov 2026

Winding diagrams have no single standard. An engineering article on the subject says several conventions exist and many diagrams are incomplete: some do not show terminals or interconnections, so the polarities are not defined. Reading one means collecting a few numbers first.

The checklist

  1. Winding type: most larger AC machines use lap windings, in which all coils are identical, each occupying a go slot and a return slot. Coil 1 in slots 1 and 6, coil 2 in slots 2 and 7, and so on, is a progressive lap winding.
  2. Slots: count them. The number must be divisible by the number of phases for a balanced winding, and usually even.
  3. Coils and layers: each coil has two coil sides. If every slot holds two coil sides, it is a double-layer winding and the number of coils equals the number of slots.
  4. Coil span: the number of slots between the go and return sides. Some factories describe it as the throw, so a span of 5 is described as throw 6. Do not confuse the two.
  5. Poles: the stator winding defines them. Count the coil groups of one phase.
  6. Coils per pole-group: coils per phase divided by the number of pole-groups per phase.
  7. Slots per pole, and slots per pole per phase.

A worked example

A published example is a three-phase machine with 36 slots and four poles. The developed diagram, which shows the inside of the stator bore rolled out flat, has 36 coils, two coil sides per slot, drawn as diamond coils. Coils fall into groups of three, from 36 divided by 3 phases times 4 poles. Each group has a start point S at the leading tail of the first coil and a finish point F at the trailing tail of the last, to be joined to other groups.

A companion article on the induction motor reads a similar 36-slot stator. Coils lie in groups of three, with four groups per phase, so the machine has four poles. Four poles over 36 slots gives 9 slots per pole, an integer, and 3 slots per pole per phase. If each coil spans 8 slots, not 9, it is short-pitched or chorded. A group of three coils spread over 3 slot-pitches is a phase belt of 30 degrees.

Phase order

The same article notes that the spatial order of the phase windings determines direction of rotation, so check the order against the supply phase sequence.

Checks before you wind

Frequently asked questions

What is a pole-group?

The group of adjacent coils of one phase that make one pole.

How do I find the number of poles?

Count the coil groups in one phase.

What is coil span?

The number of slots between the two sides of a coil.

What does slots per pole per phase tell me?

It is used in the winding distribution factor, and higher values usually mean better harmonic performance, according to one article.

Are winding diagrams standard?

No. Conventions differ, so check what each diagram shows.

Sources

  • JMAG Engineer's Diary no. 13: winding diagram for an AC motor (developed diagram, pole-groups, S and F points)
  • JMAG Engineer's Diary no. 15: reading a winding diagram (type, poles, slots, coil span, coils per pole-group, slots per pole per phase)
  • JMAG Engineer's Diary no. 36: essential features of the induction motor (phase belt, pole-groups, short-pitched coils)