Three-Phase Motor Winding: Star and Delta Connections

By John Johnson | 2 Nov 2026

A three-phase motor has three winding groups, one for each phase of the supply. How those groups are joined, in star (also called wye) or in delta, decides the voltage each winding sees and the current the supply delivers. The designer makes the choice and the nameplate states it. Understanding it helps with wiring, troubleshooting and rewinding.

The three windings

Each phase winding has two ends. Terminal boxes commonly label them U1-U2, V1-V2 and W1-W2. A motor with six terminals in the box can be connected either way. A motor with three terminals has its connection fixed inside.

Star connection

In star, one end of each winding is tied to a common point, and the other ends go to the three supply lines. On a balanced supply each winding sees the line-to-line voltage divided by the square root of 3, about 58 percent of it. The line current equals the winding current. On a 400 V supply, each star-connected winding sees about 231 V.

Delta connection

In delta, the windings are joined end to end in a triangle and each corner goes to a supply line. Each winding sees the full line-to-line voltage. The line current is the square root of 3 times the winding current, because each line carries the difference of two winding currents 120 degrees apart.

Star and delta compared on the same supply

  • Voltage across each winding: Star: Line voltage / √3; Delta: Full line voltage
  • Winding current: Star: Equal to line current; Delta: Line current / √3
  • Line current for the same motor: Star: One third of delta; Delta: Three times star

The one-third line current is not simply 1 over the square root of 3. Two effects stack: the winding voltage falls by a factor of the square root of 3, and the way winding currents combine into line current changes by the same factor again.

Dual-voltage motors

A nameplate such as 400/690 V means the windings get their rated voltage in delta on a 400 V supply and in star on a 690 V supply. Each winding sees the same voltage in both cases. Do not assume a motor can be connected either way on any supply. Follow the nameplate and the connection it lists for your supply voltage.

Star-delta starting

A star-delta starter uses the difference above. The motor starts with its windings in star, which cuts the starting line current to about one third of direct-on-line starting. After a set time the starter switches the windings to delta for normal running. A typical starter has three contactors, a timer and an overload relay.

  • It only works with a motor that is designed to run in delta at the supply voltage, with all six winding ends brought out.
  • Starting torque falls too. In star the motor produces about one third of its direct-on-line torque, since torque varies with the square of the voltage. Star-delta starting suits loads that can accelerate with low torque, and is a poor fit for heavy loaded starts.
  • Switching from star to delta causes a short current and torque transient. The changeover time should be set so the motor is near running speed.

For how motor speed and torque relate to the starting method, see our article on slip in squirrel-cage induction motors.

Checking a winding

With the supply isolated, measure the resistance of each winding. The three readings should match closely. Measure insulation resistance between windings and to earth. Only qualified people should do this, on a motor that is isolated and verified dead, following the manufacturer's instructions. A large imbalance between the resistance readings, or a low insulation reading, calls for further investigation. A low insulation resistance can come from moisture or contamination as well as from damaged insulation, and test setup can affect the reading, so it is a signal to investigate, not proof of a damaged winding.

Frequently asked questions

How do I know whether a motor is star or delta connected?

Read the nameplate, which gives the connection for each voltage. The manufacturer's wiring diagram, usually on the terminal box lid or in the manual, shows how the links are arranged for each connection. Terminal layouts differ between makes, so do not judge the connection by how the terminals look. Work on a motor only when you are qualified, with the supply isolated and verified dead, and follow the exact diagram for that motor.

Why does star connection reduce the starting current?

Each winding sees about 58 percent of line voltage, so the winding current falls. In the supply line the current drops to about one third of the delta value.

Can a delta motor run in star on the same supply?

The motor would run with each winding at about 58 percent of its rated voltage, so it delivers far less torque. Use the connection the nameplate gives for your supply voltage.

What is the star point?

It is the common junction where the three winding ends meet in a star connection.

Can any motor use a star-delta starter?

No. The motor must be rated for delta at the supply voltage and have all six winding ends available at the terminal box. A motor with three terminals cannot be used.

Sources

  • Atlas of Engineering: star-delta line and phase currents (derivation)
  • Siemens: Starting Motors white paper (current about 1/3 in star-delta)
  • ABB Softstarter Handbook (star-delta needs a motor delta-connected in run; contactors, timer, overload)
  • Electrical Engineering Portal: star-delta motor starter (one third of DOL torque and current in star)
  • Copeland: starting methods (torque varies with the square of the voltage)
  • Wormgear Motors Online: 230/400 V vs 400/690 V motors (nameplate voltages and connections)
  • Megger: how to test a motor's insulation (moisture and contamination affect readings)