How to Read an Enamelled Copper Wire Datasheet

By Vladimir Frolov | 12 Nov 2026

Two magnet wire datasheets can look alike and describe different wires. The table of properties is only useful if you know what each line means, which test sits behind it and whether the figure is a limit or a typical result. This guide walks through a datasheet from top to bottom, using real manufacturer sheets as examples.

Start with identity

  • Standard and type: sheets list the standard they follow, such as an IEC 60317 part or a NEMA MW number. One supplier sheet for a polyurethane 180 wire lists IEC 60317-0-1, IEC 60317-51 and NEMA MW 82-C together.
  • Conductor and shape: copper or aluminium, round, square or rectangular. A NEMA MW number ends in -C for copper or -A for aluminium.
  • Insulation material and build, for example single or heavy build.
  • Size range, usually in AWG or millimetres. See magnet wire vs enamelled copper wire for how the naming works.

Thermal class

The thermal class is the temperature rating of the wire's insulation. One manufacturer's 200 degree C product is classified as Class 200 on a copper conductor and Class 220 on aluminium, so the class can depend on the conductor. The class is a wire rating, not a limit for the finished coil. See our guides on insulation classes and thermal class testing under IEC 60085.

Typical value or required value

One manufacturer's table shows two columns for each property: a typical performance and a required performance. The required figure is the specification limit the product must meet. The typical figure is what the manufacturer's tests usually give. For the same product, copper wire shows a typical dielectric breakdown of 12,200 volts against a required minimum of 5,700 volts, and a typical elongation of 38 percent against a required minimum of 32 percent. Design to the required value, not the typical one, unless you have agreed otherwise.

Mechanical properties

  • Elongation: how far the wire stretches before it breaks, expressed as a percentage. The requirement is a minimum.
  • Springback: how much the wire springs back after bending around a mandrel, in degrees. The requirement is a maximum, for example 58 degrees on one datasheet. It matters when forming coils.
  • Adherence and flexibility: the enamel must not crack after stretching and wrapping around a mandrel, stated as a multiple of the wire diameter.
  • Scrape and abrasion resistance: how well the film withstands scraping.

Electrical properties

  • Dielectric breakdown voltage: the voltage the insulation withstands in a defined test. The test arrangement, such as twisted pairs, at ambient or at a rated temperature, changes the number.
  • Continuity: the number of insulation faults in a defined length at a test voltage, for example faults per 100 feet at 1500 volts DC.

Thermal and chemical properties

  • Heat shock: whether the enamel cracks after stretching and heating, with the elongation and oven temperature given.
  • Cut-through or thermoplastic flow: the temperature at which the insulation yields under load.
  • Thermal endurance: life or temperature index from long-term ageing tests.
  • Solvent and refrigerant resistance, and solderability where it applies.

Pitfalls

  • Check the wire size a value applies to. One datasheet gives mechanical values for 0.3 mm wire only.
  • Compare like with like: same test method, same standard edition, same build.
  • Look for conditions: temperatures, weights and elongations are part of the figure.
  • Do not compare a typical value from one supplier with a required value from another.

Test methods are defined in standards such as NEMA MW 01000, whose Part 3 holds the test procedures, and ASTM D1676, which covers test methods for film-insulated magnet wire including bond strength, cut-through, dielectric breakdown, continuity and chemical resistance. If a sheet does not name its test method, ask the supplier. Also see wire insulation in coil winding.

Frequently asked questions

What is the difference between typical and required values?

Required is the specification limit the wire must meet. Typical is what the manufacturer's tests normally give. Design to the required value.

Why does a datasheet show different thermal classes for copper and aluminium?

The class depends on how the insulation system performs on each conductor. One manufacturer rates the same insulation Class 200 on copper and Class 220 on aluminium.

Is a higher breakdown voltage always better?

It is a measure of the insulation in one defined test. Check the test arrangement and size before you compare it with another sheet.

What is springback?

The angle by which a wire springs back after being bent around a mandrel. Datasheets give a maximum value.

Where are the test methods defined?

In the product standard, for example NEMA MW 01000 Part 3 or ASTM D1676, and in the IEC 60317 series for IEC types.

Sources

  • Essex Solutions: GP/MR-200 magnet wire datasheet (typical and required performance, thermal class on copper and aluminium)
  • Farnell / Multicomp Pro: enamelled copper wire datasheet (standards listing, values stated for 0.3 mm wire)
  • NEMA: MW 01000 Magnet Wire, how to use (Parts 1 to 3, -C and -A suffixes)
  • ASTM D1676: test methods for film-insulated magnet wire (scope and section list)