News, technical articles and suppliers for the coil winding industry

Coiltech Germany 2027, 17-18 March 2027, Messe Augsburg - international coil and winding exhibitionAdvertisement
Article

How to Strip Enamelled Copper Wire Safely

By Robert Marzolf | 14 Nov 2026

Enamelled wire cannot be joined to a terminal until the enamel is gone from the end. Done badly, stripping nicks or weakens the conductor, leaves residue, or exposes the operator to fumes. This guide covers the methods manufacturers describe and the care each needs.

Three methods

One manufacturer's precautions list three ways to remove the insulating coating: electric burning, mechanical stripping and chemical treatment. Select the one that suits your work type and process. NEMA also publishes a short document, Magnet Wire Insulation Removal Methods, which describes known methods, their typical applications and safety precautions. Read it alongside your supplier's guidance.

Electric burning

Thermal removal burns the enamel off using heat. It produces fumes, so use ventilation. Check the wire type first, because enamels differ in how they respond to heat. Some wire is made with a solderable enamel, which can be removed by the heat of the soldering process itself. That is a property of the specific wire, so check the datasheet before relying on it. Non-solderable classes must be stripped first and can then be soldered or mechanically terminated.

Mechanical stripping

Mechanical methods scrape or abrade the enamel away. The manufacturer's warning is to take care not to scratch the conductor too deeply. A nicked conductor is a weak point, and on fine wire it can break. After stripping, inspect the bare copper under good light or magnification and cut back and redo the end if it is nicked.

Chemical treatment

Chemical removers dissolve the enamel. The manufacturer gives these cautions: prevent the remover from touching parts that are not to be stripped, and wipe off residual chemical afterward. On smaller and thinner wires, follow the instructions closely, because the conductor can break through corrosion. Read the safety data sheet for the remover and follow it.

Safety

  • Wear safety gloves and eye and face protection.
  • Use adequate ventilation or breathing protection to avoid breathing fumes.
  • Do soldering under a vented fume hood.
  • Keep chemicals and ignition sources apart and store removers as their data sheet says.
  • Remove only the length you need, and keep stripped ends clean.

Check the result

After stripping, the end should show clean copper with no remaining enamel, no deep scratches and no chemical residue. Where the end will be soldered, a visual check of the joint is also useful; one litz wire supplier suggests examining a crosscut at 100 times magnification to confirm the solder has reached each strand. For terminations on a production line, follow the process your supplier or customer specifies. For wire quality in general, see wire insulation in coil winding and winding tension.

Frequently asked questions

What are the ways to strip enamelled copper wire?

Electric burning, mechanical stripping and chemical treatment are the three methods one manufacturer lists. Choose by wire type and process.

Can I just solder through the enamel?

Only if the wire is made with a solderable enamel. Check the datasheet. Non-solderable wire must be stripped first.

How do I avoid damaging the conductor?

With mechanical methods do not scratch the copper too deeply. With chemicals, keep the remover off unstripped areas, wipe off residue, and take extra care on thin wire.

What protective equipment is needed?

Gloves, eye and face protection, and ventilation or breathing protection. Solder in a vented fume hood.

Where can I find the detailed procedure?

In your wire supplier's instructions and in the NEMA publication on magnet wire insulation removal methods.

Sources

  • Shibata (Furukawa agent): precautions for use, magnet wire stripping
  • NEMA: Magnet Wire Insulation Removal Methods (publication description; full text not read)
  • New England Wire Technologies: litz wire termination guide (solderable enamel, safety, solder joint check)