News, technical articles and suppliers for the coil winding industry

Coiltech Germany 2027, 17-18 March 2027, Messe Augsburg - international coil and winding exhibitionAdvertisement
Article

Motor Winding Pitch and Coil Span Explained

By Jeff Perry | 4 Nov 2026

Two numbers in a winding diagram cause most mistakes: coil span and coil pitch. They are related, but they are not the same.

Definitions

  • Slots per pole: slots divided by poles. This is the pole pitch measured in slots.
  • Coil span: the number of slots between the go side and the return side of a coil.
  • Coil pitch: equivalent to span, but used more in theory and expressed in electrical degrees or as a fraction of the pole pitch, according to a winding article.
  • Full pitch: a coil span equal to the pole pitch.

A lecture source explains that one pole pitch is always 180 electrical degrees, however many poles the machine has, and that the two sides of a coil should lie under adjacent poles for maximum EMF so their EMFs add directly.

A short-pitch example

The lecture's example is a 24-slot, 4-pole machine. A full-pitch coil has its sides in slots 1 and 7. A short-pitch coil is placed in slots 1 and 6, a span of 5/6 of a pole pitch, falling short by 30 electrical degrees. In a 48-slot, 8-pole example in another article, the pole pitch is 6 slots and a coil with a span of 5 slots has a pitch of 5/6, or 150 electrical degrees. A 36-slot, 4-pole stator with coils spanning 8 slots against a pole pitch of 9 is also short-pitched, or chorded.

Why short pitch

The lecture lists advantages: it saves copper in the end connections because the coils are shorter, it makes the generated EMF waveform more nearly sinusoidal by eliminating distorting harmonics, and it reduces eddy-current and hysteresis losses and so raises efficiency. The disadvantage is a somewhat lower total voltage, because the voltages in the two sides are slightly out of phase. The source gives about 3 percent as the loss for the standard 5/6 pitch.

The throw trap

Some factories describe the span as the throw. A winding article gives the example that a span of 5 slots is described as throw 6, meaning wound in slots 1 and 6. Do not confuse the 6 with the 5. When you read a diagram, check which one is meant.

Practical checks

  1. Count slots and poles, then compute slots per pole. See how to read a three-phase motor winding diagram.
  2. Find the span from a coil's go and return slots.
  3. Compare span with slots per pole to see if it is short pitch.
  4. Check that every coil has the same span.
  5. Record it before you strip a winding. See induction motor winding design and manufacturing basics.

Frequently asked questions

What is coil span?

The number of slots between the two sides of a coil.

What is a short-pitched coil?

One whose span is less than the pole pitch.

Why use short pitch?

Shorter end connections and a cleaner voltage waveform.

What does it cost?

A small reduction in voltage, about 3 percent at 5/6 pitch according to one source.

What is throw?

A factory term for the span counted as the slot number, so span 5 can be called throw 6.

Sources

  • Engineering Devotion: MMF of distributed windings and winding factors (slots per pole, coil span, short-pitch windings, pitch factor)
  • JMAG Engineer's Diary no. 15: reading a winding diagram (coil span, coil pitch, throw, slots per pole)
  • JMAG Engineer's Diary no. 36: essential features of the induction motor (short-pitched or chorded coils, phase belt)