Motor Winding Pitch and Coil Span Explained
Two numbers in a winding diagram cause most mistakes: coil span and coil pitch. They are related, but they are not the same.
Definitions
- Slots per pole: slots divided by poles. This is the pole pitch measured in slots.
- Coil span: the number of slots between the go side and the return side of a coil.
- Coil pitch: equivalent to span, but used more in theory and expressed in electrical degrees or as a fraction of the pole pitch, according to a winding article.
- Full pitch: a coil span equal to the pole pitch.
A lecture source explains that one pole pitch is always 180 electrical degrees, however many poles the machine has, and that the two sides of a coil should lie under adjacent poles for maximum EMF so their EMFs add directly.
A short-pitch example
The lecture's example is a 24-slot, 4-pole machine. A full-pitch coil has its sides in slots 1 and 7. A short-pitch coil is placed in slots 1 and 6, a span of 5/6 of a pole pitch, falling short by 30 electrical degrees. In a 48-slot, 8-pole example in another article, the pole pitch is 6 slots and a coil with a span of 5 slots has a pitch of 5/6, or 150 electrical degrees. A 36-slot, 4-pole stator with coils spanning 8 slots against a pole pitch of 9 is also short-pitched, or chorded.
Why short pitch
The lecture lists advantages: it saves copper in the end connections because the coils are shorter, it makes the generated EMF waveform more nearly sinusoidal by eliminating distorting harmonics, and it reduces eddy-current and hysteresis losses and so raises efficiency. The disadvantage is a somewhat lower total voltage, because the voltages in the two sides are slightly out of phase. The source gives about 3 percent as the loss for the standard 5/6 pitch.
The throw trap
Some factories describe the span as the throw. A winding article gives the example that a span of 5 slots is described as throw 6, meaning wound in slots 1 and 6. Do not confuse the 6 with the 5. When you read a diagram, check which one is meant.
Practical checks
- Count slots and poles, then compute slots per pole. See how to read a three-phase motor winding diagram.
- Find the span from a coil's go and return slots.
- Compare span with slots per pole to see if it is short pitch.
- Check that every coil has the same span.
- Record it before you strip a winding. See induction motor winding design and manufacturing basics.
Frequently asked questions
What is coil span?
The number of slots between the two sides of a coil.
What is a short-pitched coil?
One whose span is less than the pole pitch.
Why use short pitch?
Shorter end connections and a cleaner voltage waveform.
What does it cost?
A small reduction in voltage, about 3 percent at 5/6 pitch according to one source.
What is throw?
A factory term for the span counted as the slot number, so span 5 can be called throw 6.
Sources
- Engineering Devotion: MMF of distributed windings and winding factors (slots per pole, coil span, short-pitch windings, pitch factor)
- JMAG Engineer's Diary no. 15: reading a winding diagram (coil span, coil pitch, throw, slots per pole)
- JMAG Engineer's Diary no. 36: essential features of the induction motor (short-pitched or chorded coils, phase belt)