Surge Comparison Testing for Motor Windings
The surge test compares. It does not measure a single number. The winding is judged by how its wave looks next to the wave of an identical winding. This article is about reading that comparison. For the purpose and voltage see surge testing of electric motor windings.
What is compared
A tester maker explains that the pulses produce a decaying wave in the circuit of tester plus winding. The frequency, shape and amount of ringing, meaning the number of wave peaks, depend on the resistance, inductance and capacitance of the winding. The wave is compared with the wave from another coil or from the other phases of the motor, all shown on one screen. A highly damped load such as a small assembled motor may show only one peak, and rotors dampen the ringing.
Good and bad
- Good: if the coils or phases are identical, with the same impedance, the waves are nearly identical and overlap.
- Bad: if there is a fault or insulation weakness, the wave of the faulty winding has a different frequency from the others and its zero crossings shift to the left.
The maker's testers calculate and display the difference between pairs of waves, the percent wave difference, for phase pairs 1-2, 2-3 and 3-1. It gives 0.3 to 0.8 percent as typical for a good test, with all three phases overlapping. That is one maker's description of its own instrument. For pass and fail limits use your standard or your instrument maker's recommendations.
Assembled motors
In an assembled motor, the rotor can affect the inductance of each phase differently through transformer action. If it does, the waves for each phase differ depending on the angular position of the rotor, so a difference between phases on an assembled motor does not by itself prove a fault. Repeat the test with the rotor in another position before drawing a conclusion.
Why comparison works
Weak turn insulation is hard to find with simple tests. The maker explains that the surge test is the only test that can find weak insulation at elevated voltage, and that it can find wrong turn counts and wrong connections. Because the pulses make the winding ring at a frequency set by its resistance, inductance and capacitance, a shorted turn changes the inductance and so changes the wave. Comparing against a known-good winding, or against the other two phases of the same stator, shows that change without needing a stored reference value.
The maker also says surge tests are done on individual coils, stators, wound rotors and fully assembled motors without turning the rotor, so the same comparison idea can be used at coil winding, after insertion and after assembly.
A practical routine
- Check winding resistance and insulation resistance first. See motor winding resistance testing.
- Set the test voltage as the standard or procedure requires.
- Compare the three phase waves.
- If waves differ, repeat with the rotor turned to another position.
- Record test voltage, the waves and the percent difference.
Frequently asked questions
What is a surge comparison test?
A surge test in which the wave from one winding is compared with the waves of the others.
What shows a fault?
A different frequency and a shift of the zero crossings in the faulty wave.
What is the wave difference percentage?
A figure some testers show for the difference between two phase waves.
Does the rotor matter?
Yes. On assembled motors rotor position can change the phase waves.
Does a good wave comparison prove the winding is fine?
No. Use it with resistance and insulation tests.
Sources
- Electrom Instruments: surge test values and diagnostics, surge comparison test pass/fail recommendations (manufacturer of test equipment)
- IEEE SA: IEEE 522-2023 guide for testing turn insulation of form-wound stator coils (scope; VFD spikes not addressed)