Breakdown Voltage Test for Enamelled Copper Wire

By Robert Marzolf | 20 Nov 2026

Breakdown voltage is a type test of the enamel film. The wire is stressed until the insulation fails, and the voltage at failure is recorded. The method comes from IEC 60851-5, Test 13. This article summarises the principle from the standard's published scope, a preview copy and an independent technical review. Use the standard for the full procedure.

The principle

The test voltage is AC at 50 Hz or 60 Hz nominal frequency. It is applied starting from zero and raised at a uniform rate. A review of the standard describes the general principle: the specimen touches a metal electrode, or is twisted on itself so that two segments of the same wire act as electrodes, and voltage rises until a detection circuit sees leakage current above 5 mA. The voltage at that moment is recorded as the breakdown voltage.

Rate of voltage rise

The preview copy gives the rate as a function of the expected breakdown voltage: 20 V/s up to and including 500 V, 100 V/s from 500 V up to and including 2500 V, and 500 V/s above 2500 V. The equipment includes a test transformer rated at least 500 VA and a fault detection circuit operating at 5 mA or more.

Specimen preparation

The standard gives different preparations depending on the wire. The preview contents list a cylinder method with a polished metal cylinder 25 mm in diameter, a twisted specimen, a U-bend specimen placed in a shot bath, and a coil-wound specimen, with an overview table of which method applies to which wire. Which one you use depends on the wire's size, insulation grade and type.

Number of tests

The review says that for each test configuration five specimens are tested and one measurement is recorded from each.

Using the result

  • It is a measure of the film's ability to withstand a voltage ramp under the test conditions, not a working voltage. A coil in service sees heat, vibration, moisture and surges. See thermal class of magnet wire.
  • Compare with the minimum in the product standard or the datasheet. See how to read an enamelled copper wire datasheet.
  • Do not compare numbers made with different methods or ramp rates.

Limits of the method

A 2025 conference paper on winding wire tests says that its authors set out to overcome some limitations in the IEC 60851-5 procedure, and compared the standard steel ball method, a common industrial saltwater immersion method and a proposed alternative. If your lab uses a method other than the one in the standard, record it. See also pinholes in magnet wire insulation.

Frequently asked questions

What does the test measure?

The voltage at which the insulation fails under a rising AC voltage.

What current counts as failure?

A fault detection circuit operating at 5 mA or more in the standard's equipment list.

How fast is the voltage raised?

20 V/s up to 500 V, 100 V/s from 500 to 2500 V and 500 V/s above 2500 V, in the edition previewed.

How many samples?

Five specimens per configuration, according to one review of the standard.

Is breakdown voltage the same as working voltage?

No. Working voltage is set by design rules and margins.

Sources

  • IEC: IEC 60851-5 winding wires test methods, electrical properties (scope: resistance, breakdown voltage, continuity, dissipation factor, pin hole)
  • IEC 60851-5 ed 5.0 preview copy (test voltage frequency, rates of voltage increase, fault current detection, specimen preparation methods)
  • Lectromec: IEC 60851-5 winding wires electrical property test methods (breakdown voltage principle, continuity, dissipation factor, pin hole)
  • IEEE CEIDP 2025: enhanced measurement accuracy of AC breakdown test in winding wires (limitations of the IEC 60851-5 procedure; steel ball and saltwater methods)