Pinholes in Magnet Wire Insulation: Causes and Testing

By Knuth Nick | 13 Nov 2026

Enamel on magnet wire is thin, and no commercial process makes it perfect. A pinhole, a thin spot or a scrape is a place where the insulation is weaker than the rest of the wire. In a finished coil, a flaw like that can matter. This article explains where faults come from and how wire makers find and count them.

What a fault is

Wire manufacturers cannot promise a wire with no faults. As one technical paper puts it, the best they can usually assure is that any wire will have no more than a specified number of faults in the insulation per 100 feet. To back that up they test the wire continuously for discontinuities in the coating, normally as it leaves the enamelling oven and before it is wound on spools.

Where faults come from

The same paper groups faults by origin. The list below is its classification and is one researchers' view, not a standard:

  • Copper rod defects, such as cracks, oxides and slivers.
  • Wire drawing damage, such as scratching and scraping, and compacted copper fines.
  • Bare wire contamination, such as copper fines, surface oxides, and oil, grease or lubricant.
  • Enamel film damage, such as mechanical damage and peel-back.
  • Airborne contaminants, such as burnt enamel and copper oxide.
  • Enamelling defects, such as air bubbles, gel particles and pinholes.

So a pinhole is one of several fault types, and many have causes before the wire reaches the enamelling oven. A clean, well-drawn conductor is the first step.

High-voltage continuity testing

The usual in-line check is a high-voltage DC continuity test. In the arrangement described, the wire runs at a constant speed over a V-grooved electrode, with the conductor earthed and a DC test voltage applied between the electrode and the conductor. A flaw lets a small current pass, which a detector registers as a fault, and the faults are counted. The fault current is limited to a few microamps so the wire is not damaged. Counting this way is non-destructive, which is why it can run on the whole length of wire.

NEMA MW 1000 (now MW 01000) covers the procedure in its Part 3. The contents of the 2015 edition list high-voltage DC continuity for 14 to 44 AWG and low-voltage DC continuity for 45 to 56 AWG, and the 2018 edition has tables of test voltages and maximum fault count per 100 feet. Finer wire is tested at low voltage. Fault limits are in the standard for each type and size, so we give none here.

What the number on a datasheet means

A continuity figure on a datasheet is a fault count over a defined length at a stated voltage. One manufacturer's data lists faults per 100 feet at 1500 volts DC, using a brush electrode, with a typical result and a required limit for each conductor. Treat it like any datasheet figure: check the length, the voltage and the method before you compare. See how to read an enamelled copper wire datasheet.

What a user can do

Continuity testing at the wire maker finds faults in the wire. It does not replace testing of the finished coil.

Frequently asked questions

What is a pinhole in magnet wire?

A small flaw in the enamel film. It is one of several fault types that continuity testing counts.

How are faults detected?

By running the wire over an electrode with a DC high voltage applied. A flaw lets a small current pass and it is counted as a fault.

Can manufacturers guarantee zero faults?

One technical paper says they typically assure no more than a specified number per 100 feet, not none.

Why is fine wire tested differently?

NEMA MW 1000 lists low-voltage continuity for 45 to 56 AWG and high-voltage continuity for 14 to 44 AWG.

Does a good continuity result mean the coil will pass?

No. It describes the wire as made. Winding damage and coil-level faults need coil tests.

Sources

  • IJERT: High voltage DC testing on enamelled copper wires (continuity test principle, fault classification and causes; a researchers' paper)
  • ANSI/NEMA MW 1000-2015 and 2018 previews (contents only): Part 3 test procedures, 3.9 continuity (high-voltage 14 to 44 AWG, low-voltage 45 to 56 AWG)
  • ANSI/NEMA MW 1000-2018 preview (contents only): Table 38 test voltages and maximum fault count per 100 feet
  • Essex Solutions: GP/MR-200 datasheet (continuity test arrangement and limits as an example)
  • NEMA: MW 01000 Magnet Wire (redesignation, high-voltage continuity revisions)