How to Test Dielectric Strength of Magnet Wire
There is no single test that tells you everything about the insulation on a wire. IEC 60851-5 groups the electrical tests: electrical resistance, breakdown voltage, continuity of insulation, dielectric dissipation factor and pin hole. Four of them bear on dielectric performance.
1. Breakdown voltage
A rising AC voltage is applied until a fault current of 5 mA or more is detected. The details are in the article on the breakdown voltage test for enamelled copper wire. It tells you about the film's strength at one spot per specimen.
2. Continuity of insulation
A technical review describes continuity as the number of faults per length of wire detected by an electrical test circuit. For very fine wire, up to 0.05 mm, the wire is drawn between two felt pads wet with an electrolytic solution. For larger wire a graphite brush or grooved electrode is used. A detection circuit counts the faults, and the number found over a 30 m length is reported. The standard's contents also list high-voltage DC continuity with pulleys, and in-line and off-line test voltages by grade. This test finds weak spots along a length that breakdown voltage on a short specimen cannot.
3. Dielectric dissipation factor
The review describes dissipation factor as a measure of an insulating material's inefficiency. The wire is placed in a fixture, in a metal electrode bath or with a conductive suspension electrode, so the conductor and the outer electrode act as capacitor plates, and the value is read from an impedance meter. A low value means a more efficient insulator. A wire enamel supplier also recommends this test for monitoring the degree of cure in production.
4. Pin hole
The review calls the pin hole test essentially a visual examination after conditioning: a brief oven exposure, an aqueous sodium chloride exposure and one minute of applied voltage with a short-circuit current limit. The specimen is then examined for pin holes and the number is reported. See pinholes in magnet wire insulation.
Putting the tests together
- Use breakdown voltage for type testing and for comparing film builds.
- Use continuity to check along the length. It is the one that finds sparse faults.
- Use dissipation factor to watch the cure and the insulation quality.
- Use pin hole testing after the wire sees salt exposure in the test.
Practical points
- Follow the standard, including specimen preparation and ramp rate, and record the method.
- High voltage tests are hazardous. Use proper equipment and procedures.
- Compare results with the standard or datasheet. See how to read an enamelled copper wire datasheet.
Frequently asked questions
Is dielectric strength the same as breakdown voltage?
In practice breakdown voltage is the test that gives a number in volts, but other tests such as continuity also show insulation quality.
Which test finds isolated faults?
Continuity of insulation, which scans a length of wire.
What does dissipation factor show?
How lossy the insulation is as a dielectric.
What is the pin hole test?
A conditioning and visual count of holes after salt solution and voltage.
Where is the method defined?
IEC 60851-5.
Sources
- IEC: IEC 60851-5 winding wires test methods, electrical properties (scope: resistance, breakdown voltage, continuity, dissipation factor, pin hole)
- IEC 60851-5 ed 5.0 preview copy (test voltage frequency, rates of voltage increase, fault current detection, specimen preparation methods)
- Lectromec: IEC 60851-5 winding wires electrical property test methods (breakdown voltage principle, continuity, dissipation factor, pin hole)
- Industrial Summit Technology: Pyre-M.L. wire enamel technical bulletin (supplier; dependence of properties on degree of cure, dissipation factor, water and dielectric liquids)