Insulation Failure in Motor Windings: Causes and Prevention
Insulation fails for a small number of reasons. Knowing them shows what to prevent.
Heat
Heat ages insulation. An IEEE presentation gives a rule of thumb that a 10 C rise in temperature halves the life of the insulation system, and defines insulation class as the maximum hot-spot temperature at which the system can run for its normal expected service life. See motor winding temperature classes. EASA lists thermal causes: overload, locked rotor or excessive starts, and unbalanced voltage that heats one phase.
Prevention: run within the class, size the motor to the load, limit starts, and control voltage and ambient temperature.
Supply faults
- Single-phasing from an open phase: blown fuse, open contactor, broken line or bad connection.
- Voltage unbalance from unbalanced loads, poor terminal connections or high resistance contacts, where a one percent voltage unbalance may give a six to ten percent current unbalance.
- Under-voltage and over-voltage beyond NEMA limits.
Prevention: phase loss and unbalance protection, and good connections. See common motor winding defects for the failure patterns.
Electrical stress
EASA lists voltage surges from switching of power circuits, lightning, capacitor discharges and solid-state devices. In high-voltage machines, partial discharge in voids and on surfaces attacks the insulation. See partial discharge in motor windings. In inverter-fed motors see corona-resistant magnet wire.
Prevention: surge protection, a suitable insulation system and testing. A test equipment maker says weak turn-to-turn insulation is the source of most winding failures, and that the surge test is the only test that can find weak insulation at elevated voltage. See surge testing of electric motor windings.
Contamination, abrasion and vibration
EASA gives contaminants, abrasion and vibration, with surge, as typical causes of turn-to-turn, coil, phase-to-phase and ground failures. Loose coils can be a cause too: an ABB white paper describes a motor in which loose coils in the slots caused mechanical erosion of the insulation that would have eventually failed it.
Prevention: keep the motor clean, protect it against moisture and dust, and check that coils are tight and bracing intact.
Repair
A bad rewind adds risk. See motor rewinding vs new motor winding and induction motor winding design and manufacturing basics.
A simple prevention routine
- Record winding resistance and insulation resistance on a schedule. See motor winding resistance testing.
- Surge test after repair and during planned outages.
- Check supply balance and protection settings.
- Keep the motor clean and cool.
- Investigate the cause of every failure before the replacement runs.
Frequently asked questions
What is the most common cause of insulation failure?
One test equipment maker says weak turn-to-turn insulation is the source of most winding failures. Other sources list heat and supply faults.
Does temperature matter?
Yes. A rule of thumb says 10 C more halves insulation life.
Can voltage unbalance damage windings?
Yes. A one percent voltage unbalance may give six to ten percent current unbalance, heating one phase.
How do I prevent surge damage?
Protect against switching and surge sources and use insulation designed for them.
Which test finds weak turn insulation?
The surge test.
Sources
- IEEE NPEC: motors, styles and configurations (insulation class vs temperature rise, hot spot, 10 C rule of thumb)
- EASA: failures in three-phase stator windings (single-phasing, overload, unbalance, locked rotor, surge, contaminants)
- Electrom Instruments: surge test values and diagnostics, surge comparison test pass/fail recommendations (manufacturer of test equipment)
- ABB: controlling partial discharge in high voltage motors and generators (white paper; internal and external PD, effects, interpretation limits)
- EASA and AEMT study of motor repair impact on efficiency, ACEEE 2003 (burnout and stripping damage)